  1. TECHNICAL BULLETIN
  2. 8/8/91
  3.  
  4.                 SUPPORTED CABLES FOR USE ON LANTASTIC NETWORKS:
  5.  
  6. ARTISOFT 2 MEGABIT ADAPTERS:
  7.       1. Artisoft Dual Twisted Pair -- 1500 feet (457 meters) total
  8.             cable length per segment
  9.       2. Belden DTP 9729 or 89729 -- 1000 feet (304 meters) total
  10.             cable length
  11.       3. Phone grade DTP, 24 gauge, 100 ohm -- 300 feet (91 meters)
  12.             total cable length
  13.       4. Standard db9 connector using pins 3, 4, 7, 8.
  14.  
  15. LANZ:
  16.       1. The cable included in the network kit.
  17.       2. A standard null modem cable may work with SPORT up to 50
  18.             feet (15 meters)
  19.  
  20. ARTISOFT NE3/AE2/AE3 ADAPTERS:
  21. IEEE 802.3 Thinnet (10Base2 Ethernet), 607 feet (185 meters) per
  22. segment (30 nodes):
  23.       1. Artisoft Coax RG58au
  24.       2. Belden 9907 or 89907 Coax RG58au
  25.       3. Any IEEE 802.3 compliant RG58au or RG58cu
  26.       4. BNC connectors
  27.  
  28. IEEE 802.3 Thicknet (10Base5 Ethernet), 1640 feet (500 meters)  per
  29. segment (100 nodes):
  30.       1. Belden 9880
  31.       2. db15 AUX connectors
  32.  
  33. IEEE 802.3 Twisted Pair (10BaseT Ethernet), 328 feet (100 meters)
  34. per segment (1 node):
  35.       1. Artisoft UTP
  36.       2. AT&T 104, 315, 205
  37.       3. Belden 1227A
  38.       4. RJ45 connectors
  39.  
  40.  
  41. IEEE 802.3 10BASE2 COAX CABLE CHARACTERISTICS:
  42.  
  43. 1. Characteristic Impedance:
  44.       50 ohms +/- 2 ohms.
  45.  
  46. 2. Attenuation
  47.       A 185m cable segment shall not exceed 8.5 dB measured at 10
  48.             MHz, or 6.0 dB measured at 5 MHz.
  49.  
  50. 3. Velocity of Propagation
  51.       The minimum required is 65% of C at 20 degrees Centigrade.
  52.  
  53. 4. Edge Jitter, Untapped Cable
  54.       No more than 8.0 ns in either direction at the receiving end
  55.       when 185 meters is terminated at either end and is driven at
  56.       one end with pseudorandom Manchester encoded binary data from
  57.       a data generator that exhibits no more than 1.0 ns of edge
  58.       jitter in either direction on half bit cells of exactly 1/2
  59.       BT.
  60. 5. Transfer Impedance
  61.       At 10 MHz, the impedance is 100 milliohms/meter
  62.  
  63. 6. Cable DC Loop Resistance
  64.       The sum of the center conductor resistance plus the shield
  65.       resistance, measured at 20 degrees Centigrade, shall not
  66.       exceed 50 milliohms/meter
  67.  
  68. 7. Center Conductor
  69.       Stranded, tinned copper with an overall diameter of 0.89 +/-
  70.       0.05 mm
  71.  
  72. 8. Nomenclature of Cable
  73.       RG58/au or RG58/cu
  74.  
  75. It is not advisable to mix cable types or cable from different
  76. manufacturers in any single network.
  77.  
  78. IEEE 802.3 10BASET TWISTED PAIR CABLE CHARACTERISTICS
  79.  
  80. 1. Maximum Segment Length:    100 meters from concentrator to node
  81.  
  82. 2. Maximum Segment Loss:      11.5dB total for all wire and
  83.                               connectors
  84.  
  85. 3. Maximum Segment Delay:     1000 ns
  86.  
  87. 4. Maximum Segment Impedance: 85 to 110 ohms, averaged over 5.0 to
  88.                               10 Mhz
  89.  
  90. 5. Maximum 10BASET Network:   5 sections through 4 concentrators
  91.  
  92. 6. Maximum Mixed Network:     Up to 3 thin/thick net and 2 10BASET
  93.                               sections using 4  concentrators /
  94.                               repeaters
  95.  
  96. 7. Maximum Mixed Foirl:       With 5 sections, Foirl segments
  97.                               limited to 500 meters each.
  98.                               With 4 sections and 3 concentrator
  99.                               /repeaters, Foirl segments limited to 1000
  100.                               meters each.
  101.  
  102. GENERAL CABLE INFORMATION
  103.  
  104. In no instance is flat phone cable ("silver satin") an acceptable
  105. cable.
  106.  
  107. A network Segment is defined as all of the cable and computers
  108. between two terminators.  An Ethernet repeater and an Artisoft two
  109. megabit hub act as terminators.  Note that the Artisoft
  110. 2Mbps Hub does not act as a terminator unless it is properly
  111. configured to do so by leaving all 6 jumper pairs on and using
  112. every other harmonica port.
  113.  
  114.  